Complete table of Pomp's specifications
|
Model |
Min |
POWER INPUT at.Kw
|
150 bar |
200 bar |
250 bar |
300 bar |
350 bar |
400 bar |
500 bar |
600 bar |
|
R.P.M |
SHAFT
SIZE |
WEIGHT
Kg |
|
PR 25 |
2.5 |
0.7 |
1 |
1.2 |
1.4 |
1.6 |
1.9 |
2.4 |
28 |
1450 |
17 |
12.6 |
|
PR 50 |
5 |
1.4 |
2 |
2.4 |
2.8 |
3.3 |
3.8 |
4.8 |
5.7 |
1450 |
17 |
12.6 |
|
PR 305 |
10 |
2.8 |
4 |
4.8 |
5.7 |
6.7 |
7.6 |
__ |
__ |
1450 |
30 |
33 |
|
PR 308 |
17 |
4.9 |
6.8 |
8.1 |
9.6 |
11.4 |
13 |
__ |
__ |
1450 |
30 |
33 |
|
PR 310 |
21 |
6 |
8.4 |
10 |
12.1 |
14.1 |
16.1 |
__ |
__ |
1450 |
30 |
33 |
|
PR 508 |
28 |
8 |
11.3 |
13.4 |
16.1 |
18.8 |
__ |
__ |
__ |
1450 |
30 |
39 |
|
PR 510 |
35 |
10 |
14.1 |
16.8 |
20.3 |
23.5 |
__ |
__ |
__ |
1450 |
30 |
39 |
|
PR 512 |
42 |
12.1 |
16.9 |
23.1 |
24.2 |
28.2 |
__ |
__ |
__ |
1450 |
30 |
39 |
|
PR 514 |
48 |
13.6 |
19.3 |
23 |
27.6 |
32.3 |
__ |
__ |
__ |
1450 |
30 |
39 |
|
PR 712 |
59 |
17 |
23.8 |
28.3 |
34 |
39.7 |
__ |
__ |
__ |
1450 |
34 |
42.5 |
|
PR 714 |
69 |
19.9 |
27.8 |
33.1 |
39.8 |
__ |
__ |
__ |
__ |
1450 |
34 |
42.5 |
|
PR
714EX |
67 |
25 |
35.1 |
41.8 |
__ |
__ |
__ |
__ |
__ |
1450 |
34 |
42.5 |
|
AHP
195 |
32 |
9.2 |
12.9 |
15.1 |
18.4 |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
205 |
36 |
10.3 |
14.5 |
17.1 |
20.7 |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
197 |
45 |
12.9 |
18.1 |
21.6 |
25.9 |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
207 |
50 |
14.4 |
20.1 |
24 |
__ |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
199 |
58 |
16.7 |
23.4 |
27.8 |
__ |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
209 |
64 |
18.4 |
25.5 |
30.7 |
__ |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
1911 |
71 |
20.4 |
28.6 |
__ |
__ |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
|
AHP
2011 |
79 |
22.7 |
31.9 |
__ |
__ |
__ |
__ |
__ |
__ |
1000 |
35 |
24 |
Instructions for installation and starting
The hydraulic system must satisfy demands on pipe size,
filtering, Etc. In accordance with size of pump input
and also pump output installation The pump shaft may
rotate in either direction.
1- Fit the section connection. Note the size of the
section line that must be in accordance with pump input.
2- Fit the pump in any position of your choice.
3- Bleed the pump before starting it: AHP and PR 25-50
loosen the uppermost of the bleed screws by 2-3
turns. PR pumps: fill up pump from the oil before
starting.
Starting:
1- Run the pump without load for a minute or so,
preferably at full speed, if the equipment works
unevenly, there is still some air in the system.
Stop and start the pump a few times to bleed the system.
Note, |